MSII Tower

Delivers maximum power density in a compact tower design – from 4.5 to 20K

CSPM’s MSIl Tower UPS from Ablerex, is the perfect solution for mission-critical users who demand high reliability, availability, and performance for critical electronic equipment and computer loads.

Strengths & Features
  • Simple Parallel Installation
  • Full-time Digital Signal Processor Control
  • Programmable Frequency Converter
  • LCD/LED Mimic Panel
  • Multi-Mode Operation
  • Simple and Easy to Use
  • Optional Galvanic Isolation Transformer
  • Optional Hot Swappable Battery
Conformity to standards
  • EN62040-1-1, UL1778, EN62040-1-1
  • EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A, EN62040-2
  • CE, cUL, UL, CE

Technical data

Model MSII4500 MSII6000 MSII8000 / 8000P MSII10000 / 10000P MSII15000 MSII20000
Input Voltage 160~280Vac(1Φ) 160~280Vac (1Φ) / 277 – 485Vac (3Φ)** 277~485Vac(3Φ) **
Frequency 45 ~ 65 Hz
Phase 1Φ, Line + Neutral + Ground 1Φ, Line + Neutral + Ground;
3Φ, R, S, T + Neutral + Ground
3Φ, R, S, T + Neutral + Ground
Power Factor Up to 0.99(1Φ) / 0.95(3Φ) at Linear Load
Output Voltage & Voltage Tolerance 200/208/220/230/240Vac (Selectable) ± 1%
Capacity 4050W 5400W 7200W 9000W 13500W 18000W
Frequency (Battery Mode) ±1Hz or ±3Hz (Selectable)
Current Crest Ratio 3:1
Harmonic Distortion < 1% at Linear Load
Output Waveform Pure sine wave
Transfer Time (AC to DC) 0ms
Efficiency
DC Start Up to 90% (Line Mode) Up to 90% (without Transformer)
Battery Number of batteries 20pcs
Type Sealed Lead Acid Maintenance Free
Capacity 12V/5AH or 12V/7AH 12V/9AH 12V/7AH N/A
Rated Battery Voltage 240Vdc
Recharge Time + 90% 5 hours N/A
Display Status On LED + LCD Line Mode / Backup Mode / ECO Mode / Bypass Supply / Battery Low / Battery Fault / Overload / Transferring with interruption / UPS Fault
LCD Input Voltage / Input Frequency / Output Voltage / Output Frequency / Load Percentage / Battery Voltage / Temperature
Self-Diagnostics Upon Power-on / Front Panel Setting & Software Control / 24-hour routine checking
Alarms Audible and Visual Line Failure / Battery Low / Transfer to Bypass, System Fault Conditions
Protection Overload Capacity Inverter Supply: 105%~150% for 160 seconds ~ 2 cycles before switching bypass.
Bypass Supply: 105%~200% for 500 seconds ~8 cycles before stopping supply load.
Short Circuit Breaker / Electronic Circuit
EPO Output shuts down immediately
Over Temperature Normal Mode : Transfer to Bypass Mode
Battery Mode : UPS shuts down immediately
PHYSICAL Tower model Dimensions (WxHxD,mm/inch) w/o transformer 290x748x645 / 11.4x25.4x29.5 290x748x645 / 11.4x25.4x29.5
with transformer 290x748x645 / 11.4x25.4x29.5 290x881x645 / 11.4x25.4x34.7 290x1014x645 / 11.4x25.4x39.9
Weight (kg/lbs) (w/o transformer) Standard Unit/ Hot Swappable unit 86/190 8K:87/192 10K: 96/215 60/132
8KP:92/202.4 10KP: 101/223
Weight (kg/lbs) (with transformer) Standard Unit/ Hot Swappable uni 120/264 8K:140/308 10K: 149/327.8 130/286
8KP:145/319 10KP: 154/228.8
PHYSICAL Mini Tower Model 1Φ/1Φ Dimensions (WxHxD,mm/inch) 220x440x658 / 8.66x17.3x25.9 N/A
Weight (kg/lbs) 69.5/153.2 (7AHx20) 74.5/164.3 (9AHx20) N/A
PHYSICAL Mini Tower model 3Φ/1Φ Dimensions (WxHxD,mm/inch) N/A 290x615x645 / 11.4x24.2x25.4 290x748x524 / 11.4x29.4x20.6
Weight (kg/lbs) N/A 96/211.6 (9AHx20) 41/90.4
Environmental Operating Temperature 0~40°C / 32~104°F
Noise Level (1m front) <50dBA <60dBA
Altitude 1000m / 3280ft (Without derating)
Humidity 0%~90%RH (Without condensation)
Interface Interface Type Standard RS232 Interface Standard RS232, EPO
Communication Slots 2 nd RS232, USB, RS485, Relay Contact, SNMP/WEB Card, etc.
Compatible platforms Microsoft Windows series, Linux, Mac, etc
Standard and Certifications Safety EN62040-1-1, UL1778 EN62040-1-1
EMC EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A EN62040-2
Markings CE, cUL, UL *** CE

 

Battery Bank Specifications
UPS model Code Bat. Type Max. Quantities Dimensions (WxHxD, mm/inch)
MSII 4500 / 6000VA T40JXX07 7AH 40 290x748x631 / 11.4x29.4x24.8
MSII 4500 / 6000VA T60JXX07 7AH 60 290x748x631 / 11.4x29.4x24.8
MS II 8000 / 10000VA T40NXX09 9AH 40 290x748x631 / 11.4x29.4x24.8
MS II 8000 / 10000VA T60NXX09 9AH 60 290x748x631 / 11.4x29.4x24.8
MSII15000VA / 20000VA T60VXX09 9AH 60 290x748x631 / 11.4x29.4x24.8
MSII15000VA / 20000VA T40VXX12 12AH 40 290x748x631 / 11.4x29.4x24.8

 

* Specifications subject to change without notice.
** Based on load precentage.
*** Depending on the model and voltage, Please contact Ablerex for more information.
**** The same technical specification may be sold in different countries under different model names, please consult Ablerex for more information.

System

System or product options
  • Available in a variety of Full-sized and Mini Tower dimensions.
  • Hot Swappable Units available.
  • With or without transformer.

Communication

Software features
  • RS232, USB, EPO.
  • Compatible with Microsoft Window series, Linux, Mac, etc.
Communication options
  • Standard RS232 Interface, Standard RS232, EPO.
  • 2nd RS232, USB, RS485, Relay Contact, SNMP/WEB Card, etc.

We’re here to help

Our technical experts are on hand to answer any questions on installation,
commissioning, maintenance, product selection and software updates.